EX-8
Available Capacities:
|
|
|
|
|
Included accessories:
Input Power Cords, Type F, Type G, Type I, Type M.
Download / View User's Manual
Download / View Brochure
Notice: Last items in stock!
Availability date: 05/20/2020
SPECIFICATIONS
| STEP-DOWN Voltage and Frequency Converter (EX Series) | |
| Model | 12060EX-8 |
| Output | |
| Capacity | 1000VA/900W |
| Output Voltage | 100V/110V/115V/120V Selectable |
| Output Current-Amps @ 60Hz |
8.4 Amp |
| OUTPUT PEAK CURRENT (<250mS) | 26 Amp |
| Voltage Regulation | ±2% of selected output voltage |
| Output Frequency (sync to mains) |
N/A |
| Output Frequency (not sync to mains) |
50/60Hz (selectable from LCD function button) 50±0.01Hz or 60±0.01Hz |
| Crest Factor | 3:1 |
| Voltage Waveform | Sine Wave |
| Output Distortion (Resistive Load) | <2% |
| Output Distortion (Reactive Load) | <3% |
| Non-Linear Peak Current for 30 sec. | 18A |
| Standby Power | 18W |
| Total Harmonic Distortion | <3% (at full resistive load) |
| Output EMI Filter | N/A |
| Output RFI Filter | 30Mhz - 1000Mhz |
| Clamp Level | 200V PEAK |
| Protection | |
| Over load Protection | 100%~129% for 60 seconds delay, then alarm ; alarm for 60 seconds, then shutdown o/p; > 130%, alarm for 2 seconds, then shutdown o/p; |
| 4A | Output protected from short circuit by pulsating type Auto-Restart time: 30 seconds |
| Input | |
| Voltage Range | 180V~285Vac |
| Maximum Continuous Load | 900W |
| Maximum Peak Load | 1200W |
| Input Current | 6 Amp |
| Input Frequency Range | 45Hz ~ 70Hz |
| Phase | Single |
| Noise Filtering | Full-Time EMI/RFI Filtering |
| Input EMI Filter | 150Khz -30Mhz (class A) |
| Input RFI Filter | 30Mhz - 1000Mhz (class A) |
| Over Current Protection | By Re-Settable Over Current Protector |
| Voltage Range | 180 V ~ 285 Vac |
| Power Factor | ≧0.98 |
| Audible Alarm | Over load alarm, Short-circuit alarm, Thermal alarm |
| Inrush Surge Capacity | <100A, 3mS |
| Voltage Interruption Ride Through |
10mS |
| Efficiency | |
| Efficiency | >89% |
| Output Connection from Mains | |
| Ground | Input and Output Ground Connected |
| Neutral | Input and Output Neutral Connected (after EMC inductor ) Isolation Transformer is not required |
| Indicators | |
| LCD Control Panel | Displays Input Voltage, Output Voltage, Output Frequency, Temperature, Load Level Selectable Output Voltage and Output Frequency |
| LED | N/A |
| Output Compatibility | |
| Output Compatibility with UPS | Yes |
| Environmental and Safety | |
| Operating Temp. | Up to 1500 meters: 0℃ to 40℃ (32℉ to 104℉) |
| Transit/storage Temp. | -15℃ to 55℃ (5℉ to 131℉) |
| Relative Humidity | 5 – 95% Non-Condensing |
| Operating Altitude | 0 ~ 3000 Meters |
| Moisture Sensitivity | Internal Fan |
| Audible Noise | ≦45 dBA (at 1 meter from surface of unit) |
| Cooling | |
| Natural Ventilation | |
| External Cooling Fan Control | Forced air cooling by internal fan |
| Physical | |
| Dimensions W×D×H | 38 × 20 × 18 cm 14.96 x 7.87 x 7.08 in |
| Weight Net/Gross | 6.5 kg 14.33 lbs |
| Shipping Dimension; Weight | 23 x 15 x 17 in; 21 lbs 59 x 38 x 43 cm; 9.53 kgs |
| Others | |
| Standard Accessories | Input Power Cords, Type F, Type G, Type I, Type M. |
| Wall Mountable | No |
| Warranty | 2 Years, Full Replacement |
| Quality Control Standard | ISO9001 |
| Approvals and Safety Markings | CE |
No customer reviews for the moment.