EX
Available Capacities:
|
|
|
|
|
Included accessories:
Input Power Cords, Type F, Type G, Type I, Type M.
Download / View User's Manual
Download / View Brochure
Notice: Last items in stock!
Availability date: 05/20/2020
SPECIFICATIONS
STEP-DOWN Voltage and Frequency Converter (EX Series) | ||||
Model | 12060EX-8 | 12060EX-12 | 12060EX-16 | 12060EX-21 |
Output | ||||
Capacity | 1000VA/900W | 1500VA/1350W | 2000VA/1800W | 2600VA/2340W |
Output Voltage | 100V/110V/115V/120V Selectable | |||
Output Current-Amps @ 60Hz |
8.4 Amp | 12.6 Amp | 16.8 Amp | 21.8 Amp |
OUTPUT PEAK CURRENT (<250mS) | 26 Amp | 38 Amp | 50 Amp | 60 Amp |
Voltage Regulation | ±2% of selected output voltage | |||
Output Frequency (sync to mains) |
N/A | |||
Output Frequency (not sync to mains) |
50/60Hz (selectable from LCD function button) 50±0.01Hz or 60±0.01Hz | |||
Crest Factor | 3:1 | |||
Voltage Waveform | Sine Wave | |||
Output Distortion (Resistive Load) | <2% | |||
Output Distortion (Reactive Load) | <3% | |||
Non-Linear Peak Current for 30 sec. | 18A | 27A | 36A | 42A |
Standby Power | 18W | 27W | ||
Total Harmonic Distortion | <3% (at full resistive load) | |||
Output EMI Filter | N/A | |||
Output RFI Filter | 30Mhz - 1000Mhz | |||
Clamp Level | 200V PEAK | |||
Protection | ||||
Over load Protection | 100%~129% for 60 seconds delay, then alarm ; alarm for 60 seconds, then shutdown o/p; > 130%, alarm for 2 seconds, then shutdown o/p; |
|||
4A | Output protected from short circuit by pulsating type Auto-Restart time: 30 seconds |
|||
Input | ||||
Voltage Range | 180V~285Vac | |||
Maximum Continuous Load | 900W | 1350W | 1800W | 2340W |
Maximum Peak Load | 1200W | 1800W | 2400W | 3000W |
Input Current | 6 Amp | 9 Amp | 12 Amp | 15 Amp |
Input Frequency Range | 45Hz ~ 70Hz | |||
Phase | Single | |||
Noise Filtering | Full-Time EMI/RFI Filtering | |||
Input EMI Filter | 150Khz -30Mhz (class A) | |||
Input RFI Filter | 30Mhz - 1000Mhz (class A) | |||
Over Current Protection | By Re-Settable Over Current Protector |
|||
Voltage Range | 180 V ~ 285 Vac | |||
Power Factor | ≧0.98 | |||
Audible Alarm | Over load alarm, Short-circuit alarm, Thermal alarm | |||
Inrush Surge Capacity | <100A, 3mS | |||
Voltage Interruption Ride Through |
10mS | |||
Efficiency | ||||
Efficiency | >89% | |||
Output Connection from Mains | ||||
Ground | Input and Output Ground Connected | |||
Neutral | Input and Output Neutral Connected (after EMC inductor ) Isolation Transformer is not required |
|||
Indicators | ||||
LCD Control Panel | Displays Input Voltage, Output Voltage, Output Frequency, Temperature, Load Level Selectable Output Voltage and Output Frequency |
|||
LED | N/A | |||
Output Compatibility | ||||
Output Compatibility with UPS | Yes | |||
Environmental and Safety | ||||
Operating Temperature | Up to 1500 meters: 0℃ to 40℃ (32℉ to 104℉) | |||
Transit/Storage Temp | -15℃ to 55℃ (5℉ to 131℉) | |||
Relative Humidity | 5 – 95% Non-Condensing | |||
Operating Altitude | 0 ~ 3000 Meters | |||
Moisture Sensitivity | Internal Fan | |||
Audible Noise | ≦45 dBA (at 1 meter from surface of unit) | |||
Cooling | ||||
Natural Ventilation | No | |||
External Cooling Fan Control | Forced air cooling by internal fan | |||
Physical | ||||
Dimensions W×D×H | 38 × 20 × 18 cm 14.96 x 7.87 x 7.08 in |
45 × 20 × 18 cm 17.71 x 7.87 x 7.08 in |
51 × 20 × 18 cm 20.08 x 7.87 x 7.08 in |
51 × 20 × 18 cm 20.08 x 7.87 x 7.08 in |
Weight Net/Gross | 6.5k kg 14.33 lbs |
7.0 kg 15.43 lbs |
8.0 kg 17.64 lbs |
8.5 kg 18.74 lbs |
Shipping Dimension ; Weight | 25 x 15 x 17 in; 21 lbs 64 x 38 x 43 cm; 9.53 kgs |
25 x 15 x 17 in; 24 lbs 64 x 38 x 43 cm; 10.90 kgs |
28 x 15 x 17 in; 30 lbs 72 x 38 x 43 cm; 13.61 kgs |
28 x 15 x 17 in; 30 lbs 72 x 38 x 43 cm; 13.61 kgs |
Others | ||||
Standard Accessories | Input Power Cords, Type F, Type G, Type I, Type M. | |||
Wall Mountable | No | |||
Warranty | 2 Years, Full Replacement | |||
Quality Control Standard | ISO9001 | |||
Approvals and Safety Markings | CE |