PowerXchanger voltage and frequency converters are available in a variety of sizes and capacities. All Step-Down Models convert 200 V-240 V 50 Hz to 120 V 60 Hz using advanced electronic components and without the use of heavy copper wiring.
You can compare the features and specs of our different step-down converters on this comparison page.
Aside from aesthetics, size, and installation options, the main difference between the Deluxe series, Slimline series, and Economy series is fan noise. The Deluxe and Slimline series are all noise free and have sealed electronics - there are no internal fans. Cooling is done with...read more natural ventilation through the heatsinks.
On the Deluxe series there are two fans on the back, but these turn on when the unit is in distress due to overload, or excessive heat due to lack of adequate ventilation. The Deluxe and Slimline Series also come with a wall mounting kit which allows for more flexible installation options.
An additional accessory for the Deluxe Series is an Xchange Outlet which can also be wall mounted.
The Economy Series has selectable output voltage. Choose between output 100V 60Hz, 110V 60Hz, 115V 60Hz, and 120V 60Hz.
Our most powerful unit is the EX-21, it has a capacity of 2340W and max output current of 21.8 amp
Economy Series has CE mark and certification. The Deluxe and Slimline series have UL, CE, DEMKO-CB, and TUV.
There is a way to operate the Economy Series noise free, by installing the units in a different room and wire the output 120 Volts 60Hz to the point of use, using our Remote Installation Kit. These kits are also compatible with the Deluxe Series.
PowerXchanger Deluxe Series 220V 50Hz to 120V 60Hz
PowerXchanger Economy Series 220V 50Hz to 120V 60Hz
PowerXchanger Slimline Series 220V 50Hz to 120V 60Hz
KEY DIFFERENCES
DELUXE SERIES | ECONOMY SERIES | |
Efficiency | >92% | >89% |
Audible Noise | Noise Free, No Internal Fans | ≦45 dBA at 1 meter from surface of unit |
Output EMI Filter | 150Khz - 30Mhz | NO |
Moisture Sensitivity | Sealed Electronics | Internal Fan |
External Cooling Fan Control | Auto on/off, controlled by heat sink temperature & load level | NO |
Internal Cooling Fan | NO | Internal fan will run at low speed continuously when temperature inside is low and load is no more than 68%. When load level is over 70%, or when internal temperature is over 60° C, fan runs at full speed |
Output Compatibility with UPS | NOT SUGGESTED | YES |
Wall Mountable | YES | NO |
Approvals and Safety Markings | CE UL-ULus (CCN: QQFU/7) Power Units Other Than Class 2, UL 1012, Seven Edition, October 14, 2008 UL-cUL: CAN/CSA-C22.2 No. 107.1-01, September, 2001 DEMKO-CB IEC60950-1:2005+A1:2009+A2:2013 (Ed. 2.2) TUV/SUD-CB IEC 60335-1:2010+A1:2013 (Ed. 5.1) FCC: CISPR22 AND Part15B ClassB RoHS Compliant Directive 2002/95/EC |
CE |
Step-Down Voltage and Frequency Converter Comparison
PowerXchanger voltage and frequency converters are available in a variety of sizes and capacities. All Step-Down Models convert 200 V-240 V 50 Hz to 120 V 60 Hz using advanced electronic components and without the use of heavy copper wiring.
You can compare the features and specs of our different step-down converters on this comparison page.
Aside from aesthetics, size, and installation options, the main difference between the Deluxe series, Slimline series, and Economy series is fan noise. The Deluxe and Slimline series are all noise free and have sealed electronics - there are no internal fans. Cooling is done with natural ventilation through the heatsinks.
On the Deluxe series there are two fans on the back, but these turn on when the unit is in distress due to overload, or excessive heat due to lack of adequate ventilation. The Deluxe and Slimline Series also come with a wall mounting kit which allows for more flexible installation options.
An additional accessory for the Deluxe Series is an Xchange Outlet which can also be wall mounted.
The Economy Series has selectable output voltage. Choose between output 100V 60Hz, 110V 60Hz, 115V 60Hz, and 120V 60Hz.
Our most powerful unit is the EX-21, it has a capacity of 2340W and max output current of 21.8 amp
Economy Series has CE mark and certification. The Deluxe and Slimline series have UL, CE, DEMKO-CB, and TUV.
There is a way to operate the Economy Series noise free, by installing the units in a different room and wire the output 120 Volts 60Hz to the point of use, using our Remote Installation Kit. These kits are also compatible with the Deluxe Series.
PowerXchanger Deluxe Series 220V 50Hz to 120V 60Hz
PowerXchanger Economy Series 220V 50Hz to 120V 60Hz
PowerXchanger Slimline Series 220V 50Hz to 120V 60Hz
KEY DIFFERENCES
DELUXE SERIES | ECONOMY SERIES | |
Efficiency | >92% | >89% |
Audible Noise | Noise Free, No Internal Fans | ≦45 dBA at 1 meter from surface of unit |
Output EMI Filter | 150Khz - 30Mhz | NO |
Moisture Sensitivity | Sealed Electronics | Internal Fan |
External Cooling Fan Control | Auto on/off, controlled by heat sink temperature & load level | NO |
Internal Cooling Fan | NO | Internal fan will run at low speed continuously when temperature inside is low and load is no more than 68%. When load level is over 70%, or when internal temperature is over 60° C, fan runs at full speed |
Output Compatibility with UPS | NOT SUGGESTED | YES |
Wall Mountable | YES | NO |
Approvals and Safety Markings | CE UL-ULus (CCN: QQFU/7) Power Units Other Than Class 2, UL 1012, Seven Edition, October 14, 2008 UL-cUL: CAN/CSA-C22.2 No. 107.1-01, September, 2001 DEMKO-CB IEC60950-1:2005+A1:2009+A2:2013 (Ed. 2.2) TUV/SUD-CB IEC 60335-1:2010+A1:2013 (Ed. 5.1) FCC: CISPR22 AND Part15B ClassB RoHS Compliant Directive 2002/95/EC |
CE |
Which series is right for you? | ||
Slimline Series |
Deluxe Series |
Economy Series |
Xs-05GA | X-5 X-10 X-15 |
EX-8 EX-12 EX-16 EX-21 |
Appliance Mount | Table & Wall Mount | Desktop |
No Display | LCD Panel / LED | LCD Panel |
Output Capacity | ||
600VA 600W |
600VA 600W 1200VA 1200W 1800VA 1800W |
1000VA 900W 1500VA 1350W 2000VA 1800W 2600VA 2340W |
Output Voltage | ||
120Vac | 100V 110V 115V 120V Selectable |
|
Output Current-Amps @ 60Hz | ||
5.0 A | 5.0 A 10.0 A 15.0 A |
8.4 A 12.6 A 16.8 A 21.8 A |
OUTPUT PEAK CURRENT (<250mS) | ||
40 A | 40 A 40 A 45 A |
26 A 38 A 50 A 60 A |
Output Frequency (sync to mains) | ||
60Hz auto-synchronized to be 6/5 of the input mains frequency | ||
Output Frequency (not sync to mains) | ||
50/60Hz (selectable from LCD function button) 50±0.01Hz or 60±0.01Hz |
||
Standby Power | ||
15W | 18W 18W 27W 27W |
|
Output EMI Filter | ||
150Khz -30Mhz | N/A | |
Output RFI Filter | ||
30Mhz - 1000Mhz | ||
Input Voltage Range | ||
200V / 220V / 230V / 240V | 180V to 285Vac | |
Input Frequency Range | ||
46Hz ̴ 65Hz | 45Hz ̴ 70Hz | |
Input Maximum Continuous Load | ||
600W | 600W 1200W 1800W |
900W 1350W 1800W 2340W |
Input Maximum Peak Load | ||
1000W | 1000W 2000W 3000W |
1200W 1800W 2400W 3000W |
Input Current | ||
4A | 4A 8A 12A |
6A 9A 12A 15A |
Output Compatibility with UPS | ||
Not Suggested | Yes | |
Natural Ventilation Cooling | ||
Yes | No | |
External Cooling Fan Control | ||
N/A | Auto on/off, controlled by heat sink temperature & load level | Forced air cooling by internal fan |
Standard Accessories | ||
Wall Mount, Input Power Cords Type F, G, I, M with Safety Locking Connectors | Wall Mount, Input Power Cords, Type F, Type G, Type I, Type M Extension Outlet/Remote Installation Kit | Input Power Cords, Type F, Type G, Type I, Type M. |
Warranty | ||
2 Years, Full Replacement | ||
Quality Control Standard | ||
ISO9001 | ||
Quality Control Standard | ||
CE UL-ULus (CCN: QQFU/7) Power Units Other Than Class 2, UL 1012, Seven Edition, October 14, 2008 UL-cUL: CAN/CSA-C22.2 No. 107.1-01, September, 2001 DEMKO-CB IEC60950-1:2005+A1:2009+A2:2013 (Ed. 2.2) TUV/SUD-CB IEC 60335-1:2010+A1:2013 (Ed. 5.1) FCC: CISPR22 AND Part15B ClassB RoHS Compliant Directive 2002/95/EC |
CE |