SPECIFICATIONS
| STEP-DOWN Voltage and Frequency Converter (EX Series) | |
| Model | 12060EX-16 | 
| Output | |
| Capacity | 2000VA/1800W | 
| Output Voltage | 100V/110V/115V/120V Selectable | 
| Output Current-Amps @ 60Hz | 16.8 Amp | 
| OUTPUT PEAK CURRENT (<250mS) | 50 Amp | 
| Voltage Regulation | ±2% of selected output voltage | 
| Output Frequency (sync to mains) | N/A | 
| Output Frequency (not sync to mains) | 50/60Hz (selectable from LCD function button) 50±0.01Hz or 60±0.01Hz | 
| Crest Factor | 3:1 | 
| Voltage Waveform | Sine Wave | 
| Output Distortion (Resistive Load) | <2% | 
| Output Distortion (Reactive Load) | <3% | 
| Non-Linear Peak Current for 30 sec. | 36A | 
| Standby Power | 27W | 
| Total Harmonic Distortion | <3% (at full resistive load) | 
| Output EMI Filter | N/A | 
| Output RFI Filter | 30Mhz - 1000Mhz | 
| Clamp Level | 200V PEAK | 
| Protection | |
| Over load Protection | 100%~129% for 60 seconds delay, then alarm ; alarm for 60 seconds, then shutdown o/p; > 130%, alarm for 2 seconds, then shutdown o/p; | 
| 4A | Output protected from short circuit by pulsating type Auto-Restart time: 30 seconds | 
| Input | |
| Voltage Range | 180V~285Vac | 
| Maximum Continuous Load | 1800W | 
| Maximum Peak Load | 2400W | 
| Input Current | 12 Amp | 
| Input Frequency Range | 45Hz ~ 70Hz | 
| Phase | Single | 
| Noise Filtering | Full-Time EMI/RFI Filtering | 
| Input EMI Filter | 150Khz -30Mhz (class A) | 
| Input RFI Filter | 30Mhz - 1000Mhz (class A) | 
| Over Current Protection | By Re-Settable Over Current Protector | 
| Voltage Range | 180 V ~ 285 Vac | 
| Power Factor | ≧0.98 | 
| Audible Alarm | Over load alarm, Short-circuit alarm, Thermal alarm | 
| Inrush Surge Capacity | <100A, 3mS | 
| Voltage Interruption Ride Through | 10mS | 
| Efficiency | |
| Efficiency | >89% | 
| Output Connection from Mains | |
| Ground | Input and Output Ground Connected | 
| Neutral | Input and Output Neutral Connected (after EMC inductor ) Isolation Transformer is not required | 
| Indicators | |
| LCD Control Panel | Displays Input Voltage, Output Voltage, Output Frequency, Temperature, Load Level Selectable Output Voltage and Output Frequency | 
| LED | N/A | 
| Output Compatibility | |
| Output Compatibility with UPS | Yes | 
| Environmental and Safety | |
| Operating Temp. | Up to 1500 meters: 0℃ to 40℃ (32℉ to 104℉) | 
| Transit/storage Temp. | -15℃ to 55℃ (5℉ to 131℉) | 
| Relative Humidity | 5 – 95% Non-Condensing | 
| Operating Altitude | 0 ~ 3000 Meters | 
| Moisture Sensitivity | Internal Fan | 
| Audible Noise | ≦45 dBA (at 1 meter from surface of unit) | 
| Cooling | |
| Natural Ventilation | |
| External Cooling Fan Control | Forced air cooling by internal fan | 
| Physical | |
| Dimensions W×D×H | 51 × 20 × 18 cm 20.08 x 7.87 x 7.08 in | 
| Weight Net/Gross | 8.0 kg 17.64 lbs | 
| Shipping Dimension; Weight | 28 x 15 x 17 in; 30 lbs 72 x 38 x 43 cm; 13.61 kgs | 
| Others | |
| Standard Accessories | Input Power Cords, Type F, Type G, Type I, Type M. | 
| Wall Mountable | No | 
| Warranty | 2 Years, Full Replacement | 
| Quality Control Standard | ISO9001 | 
| Approvals and Safety Markings | CE | 
No customer reviews for the moment.